THPS analysis: Accurate, portable analysis in produced fluids
Helps ensuring the correct dose of THPS biocide is being applied at the target location.
The OMMICA THPS analysis kit consists of a simple, highly accurate, portable colourimetric test to determine THPS in aqueous systems.
Accuracy is gained by addition of accurately measured reagents to a sample. This is then reacted at a specific time and temperature, to control the reaction and the resultant colour gives the level of THPS.
Absorbance of the reacted sample colour is measured using a colourimeter to give an accuracy of +/- 1ppm.
The analysis has been developed to be as accurate as HPLC, but allow on-site testing to take place in the field or offshore, through use of portable equipment.
Specification Title | Specification Description |
---|---|
Areas of application
|
Can be used in any industry where THPS is used (e.g. oilfield, cooling water, etc.)
|
Accuracy
|
+/- 2 ppm
|
Detection threshold
|
< 2 ppm in water
|
Range (standard)
|
2 to 100 ppm
|
Range (extended)
|
Up to 80%
|
Quality
|
Validated by third party testing (major operator)
|
Detection threshold
|
Up to 100 samples/day possible
|
Operational impact
|
Accurate onsite testing, minimising delays
|
Deployment
|
Can be effectively used by non-specialists
|
Training
|
Dedicated YouTube training videos channel, summary videos on website, in-person training can be provided if required
|
Versatility
|
Suitable for use on or offshore. Only requires 0.5 m2 (or less) of working space. Robust equipment
|
Reviews
Sign up or log in to your explorer or platform subscription to get access to the reviews written about this technology.
The Technology Readiness Level (TRL) indicates the maturity level of novel technologies. Learn more about the TRL scale used by us.
[8/9]